Using RTC and NVRAM with backup in TPS Agent

Setup the RTC and NVRAM with backup Tibbit in LTPS Web Configurator as described in Configuring TPS Agent:

RTC and NVRAM with backup settings

Write settings and reboot LTPS.
You'll see new RTC subtab in Tibbits tab:

RTC and NVRAM with backup

The temperature in Celsius degrees.

Time and alarms are displayed in the AggreGate client with the timezone of the operating system, althrough it's read in written in UTC.

Alarm 1 triggered and Alarm 2 triggered will be set to the logic True when corresponding alarms is triggered.

If the corresponding alarm 1 enabled or alarm 2 enabled is also set to logic True, the alarm condition activates the INT/SQW signal.

The alarm flags define what calendar component to be checked against the current time in order to trigger the alarm:

RTC and NVRAM with backup settings alarm 1 settings

The logic False for Seconds, Minutes, Hours and Days activate checks.

If Wdays flag set to logic False, checks day of the month, else - day of the week.

The second alarm hasn't a seconds component:

RTC and NVRAM with backup settings alarm 2 settings

SRAM variable allows read/write up to 256 integer variables in the range from 0 to 255:

RTC and NVRAM with backup settings SRAM settings

The value updated each time AggreGate Client synchronize (3 minutes by default).